PROBLEM SYMPTOMS TABLE
HINT:
|
Symptom |
Suspected Area |
Link |
|---|---|---|
|
All functions of the air conditioning system do not operate |
IG power source circuit |
|
|
Back-up power source circuit |
|
|
|
LIN communication circuit |
|
|
|
Air conditioning amplifier assembly |
|
|
|
Air flow Control: No blower operation |
Blower motor circuit |
|
|
LIN communication circuit |
|
|
|
Air conditioning amplifier assembly |
|
|
|
Air flow control: No blower control |
Blower motor circuit |
|
|
LIN communication circuit |
|
|
|
Air conditioning amplifier assembly |
|
|
|
Air flow control: Insufficient air flow |
Blower motor circuit |
|
|
Air conditioning amplifier assembly |
|
|
|
Temperature control: No cool air comes out |
Refrigerant volume |
- |
|
Refrigerant pressure |
|
|
|
Air conditioner pressure sensor circuit |
|
|
|
LIN communication circuit |
|
|
|
Air mix damper control servo motor circuit (for driver side air mix) |
|
|
|
Air mix damper control servo motor circuit (for front passenger side air mix) |
|
|
|
Evaporator temperature sensor circuit |
|
|
|
Room temperature sensor circuit |
|
|
|
Ambient temperature sensor circuit |
|
|
|
Cooler expansion valve |
|
|
|
No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) |
|
|
|
No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) |
|
|
|
Air conditioning harness assembly |
|
|
|
Compressor with pulley assembly |
|
|
|
Air conditioning amplifier assembly |
|
|
|
ECM |
|
|
|
Temperature control: No warm air comes out |
LIN communication circuit |
|
|
Air mix damper control servo motor circuit (for driver side air mix) |
|
|
|
Air mix damper control servo motor circuit (for front passenger side air mix) |
|
|
|
Evaporator temperature sensor circuit |
|
|
|
Room temperature sensor circuit |
|
|
|
Ambient temperature sensor circuit |
|
|
|
No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) |
|
|
|
No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) |
|
|
|
Air conditioning harness assembly |
|
|
|
Air conditioning amplifier assembly |
|
|
|
ECM |
|
|
|
Temperature control: Output air is warmer or cooler than the set temperature or response is slow |
Refrigerant volume |
- |
|
Refrigerant pressure |
|
|
|
Solar sensor circuit |
|
|
|
Room temperature sensor circuit |
|
|
|
Ambient temperature sensor circuit |
|
|
|
LIN communication circuit |
|
|
|
Air mix damper control servo motor circuit (for driver side air mix) |
|
|
|
Air mix damper control servo motor circuit (for front passenger side air mix) |
|
|
|
Air inlet damper control servo motor circuit |
|
|
|
Heater radiator unit sub-assembly |
|
|
|
Cooler expansion valve |
|
|
|
No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) |
|
|
|
No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) |
|
|
|
No. 1 blower damper servo sub-assembly (fresh/recirculation) |
|
|
|
Air conditioning harness assembly |
|
|
|
Air conditioning amplifier assembly |
|
|
|
ECM |
|
|
|
Temperature control: No temperature control (only MAX COLD or MAX HOT) |
LIN communication circuit |
|
|
Air mix damper control servo motor circuit (for driver side air mix) |
|
|
|
Air mix damper control servo motor circuit (for front passenger side air mix) |
|
|
|
Room temperature sensor circuit |
|
|
|
Ambient temperature sensor circuit |
|
|
|
Evaporator temperature sensor circuit |
|
|
|
Solar sensor circuit |
|
|
|
No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) |
|
|
|
No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) |
|
|
|
Air conditioning harness assembly |
|
|
|
Air conditioning amplifier assembly |
|
|
|
Temperature control: Output air temperature is different between left and right registers (the set temperature is the same for both) |
Refrigerant volume |
- |
|
Refrigerant pressure |
|
|
|
Air mix damper control servo motor circuit (for driver side air mix) |
|
|
|
Air mix damper control servo motor circuit (for front passenger side air mix) |
|
|
|
Automatic light control sensor |
|
|
|
No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) |
|
|
|
No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) |
|
|
|
Air conditioning harness assembly |
|
|
|
Air conditioning amplifier assembly |
|
|
|
No air inlet control |
LIN communication circuit |
|
|
Air inlet damper control servo motor circuit |
|
|
|
No. 1 blower damper servo sub-assembly (fresh/recirculation) |
|
|
|
Air conditioning harness assembly |
|
|
|
Air conditioning amplifier assembly |
|
|
|
Quick heater assembly does not operate |
PTC heater circuit |
|
|
Air conditioning amplifier assembly |
|
|
|
Diagnostic trouble codes (DTCs) are not recorded. Set mode is cleared when the ignition switch is turned off |
Back-up power source circuit |
|
|
Air conditioning amplifier assembly |
|
Initialization
Terminals Of EcuToyota CH-R Service Manual > Power Door Lock Control System: Customize Parameters
CUSTOMIZE PARAMETERS
CUSTOMIZE POWER DOOR LOCK CONTROL SYSTEM
HINT:
The following items can be customized.
NOTICE:
When the customer requests a change in a function, first make sure that
the function can be customized.
Be sure to make a note of the current settings before custom ...
Toyota CH-R Owners Manual > Steps to take in an emergency: If your vehicle overheats
The following may indicate that your vehicle is overheating.
The needle of the engine coolant temperature gauge enters the red zone or
a loss of engine power is experienced (for example, the vehicle speed does not
increase).
Steam comes out from under the hood.
Correction procedures
...