Toyota CH-R Service Manual: Data List / Active Test

DATA LIST / ACTIVE TEST

ACTIVE TEST

HINT:

Using the Techstream to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.

(a) Connect the Techstream to the DLC3.

(b) Turn the ignition switch to ON.

(c) Turn the Techstream on.

(d) Enter the following menus: Body Electrical / Air Conditioner / Active Test.

(e) According to the display on the Techstream, perform the Active Test.

Body Electrical > Air Conditioner > Active Test

Tester Display

Measurement Item

Control Range

Diagnostic Note

Deicer Relay (Front)

Windshield glass (windshield deicer)

OFF or ON

-

    Terminals Of Ecu
    TERMINALS OF ECU CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY (for TMMT Made) (a) Disconnect the F72 air conditioning amplifier assembly connector. (b) Measure the voltage and resistance according t ...

    Windshield Deicer does not Operate
    DESCRIPTION When the windshield deicer switch on the air conditioning control assembly is pressed, the operation signal is transmitted to the air conditioning amplifier assembly. via LIN communic ...

    Other materials:

    Toyota CH-R Service Manual > Audio And Visual System(for Radio And Display Type): Sound Signal Circuit between Radio Receiver and Stereo Jack Adapter
    DESCRIPTION The No. 1 stereo jack adapter assembly sends the sound signal from an external device to the radio and display receiver assembly via this circuit. The sound signal that has been sent is amplified by the radio and display receiver assembly and then is sent to the speakers. If there ...

    Toyota CH-R Service Manual > Windshield Outside Moulding: Installation
    INSTALLATION CAUTION / NOTICE / HINT HINT: Use the same procedure for the RH side and LH side. The following procedure is for the LH side. PROCEDURE 1. INSTALL NO. 3 WINDSHIELD OUTSIDE MOULDING CLIP HINT: Perform the following procedure only when replacement of a No. 3 winds ...