CUSTOMIZE PARAMETERS

CUSTOMIZE METER / GAUGE SYSTEM

(a) Customizing with the Techstream.

(1) Connect the Techstream to the DLC3.

(2) Turn the ignition switch ON.

(3) Turn the Techstream on.

(4) Enter the following menus: Customize Setting / Warning or Display.

(5) Select the setting by referring to the table below.

NOTICE:

Be sure to record the current value before customizing.

Display

Tester Display

Description

Default

Setting

ECU

ECO Drive Indicator Zone

Function to change the ECO Drive Indicator Zone

ON

0:OFF,1:ON

Combination meter assembly

ECO Drive Indicator Light

Function to change the ECO Drive Indicator light*1

ON

0:OFF,1:ON

Combination meter assembly

ODO Display Time After IG OFF Setting

Function to change the ODO display time after the ignition switch is turned off

30s

00:30s,01:60s,10:600s,11:OFF

Combination meter assembly

Warning

Tester Display

Description

Default

Setting

ECU

Flasher Sound Tone Setting

Function to change the flasher sound tone

Tone 1

00:Tone 1,01:Tone 2,10:Tone 3

Combination meter assembly

Lane Change Flashing Times Setting

Function to change the lane change flashing time

3

000:OFF,001:3,010:4,011:5,100:6,101:7

Combination meter assembly

    System Description
    SYSTEM DESCRIPTION INPUT AND OUTPUT SIGNALS OF COMBINATION METER ASSEMBLY (a) Meter or Gauge Item Condition Input/Output Communication line Si ...

    How To Proceed With Troubleshooting
    CAUTION / NOTICE / HINT HINT: Use the following procedure to troubleshoot the meter / gauge system. *: Use the Techstream. PROCEDURE 1. VEHICL ...

    Other materials:

    Toyota CH-R Service Manual > Power Mirror Control System: Problem Symptoms Table
    PROBLEM SYMPTOMS TABLE NOTICE: If the battery voltage is low, the mirror heater function may not operate. In this case, check the Data List item "Battery Control Count (Body ECU)". Click here HINT: Use the table below to help determine the cause of problem symptoms. ...

    Toyota CH-R Owners Manual > Steps to take in an emergency: If the engine will not start
    If the engine will not start even though correct starting procedures are being followed, consider each of the following points: The engine will not start even though the starter motor operates normally. One of the following may be the cause of the problem: There may not be sufficient fuel in ...